Dashboard UT / Section 3: Angled / Chapter 9: Full exercises

Setup

Exercise

 

Parameters

Inspection & part

  1. Inspection: Weld
  2. Type: Plate
  3. Material: Steel
  4. Thickness: 16 mm

Hardware & position

  1. Probe frequency: 5MHz
  2. Probe size: 13 mm
  3. Wedge: 60-degree
  4. Scan offset: 0 mm
  5. Index offset: 0 mm

Scan 

  1. Wave type: Shear
  2. Scanning pattern: Rastering

UT Settings

  1. Gain: 20.1 dB
  2. Start UT range: 0 mm
  3. Range UT range: 72 mm
  4. Voltage: 100 V
  5. PRF: 100 Hz
  6. Filter: Band pass  5 MHz
  7. Video filter: off
  8. Reject: 0 %
  9. Point Quantity: 320

Instructions

  • All Silverlight exercises require the Silverlight plug-in for your web browser
  • The exercise is only active in full-screen mode

Steps

  1. Put the exercise in full-screen mode using the red button on the bottom right corner of the exercise
  2. Click on New Setup
  3. Enter the proper parameter according to the list on the left part of the exercise
  4. Click Next
  5. When all the parameters are in, click on validate