Exercise
Parameters
Calibration block
- Type: Thickness
- Material: Steel
- Thickness: 12.5 mm
Instructions
- All Silverlight exercises require the Silverlight plug-in for your web browser
- The exercise is only active in full-screen mode
Steps
- Read the thickness of the calibration block in the Parameters section
- Put the exercise in full-screen mode using the red button on the bottom right corner of the exercise
- Lower the probe on the part
- Enter the thickness of the calibration block
- Adjust the gate to cover the first backwall signal
- Start
- Range
- Threshold
- Click on Accept
- If you are not happy with the position of the line, click on Erase, position the gate and click on Accept again
- Adjust the gate to cover the second backwall signal
- Start
- Range
- Threshold
- Click on Accept
- Click on Validate
- You can use the first and third backwall for calibration if you enter 2X the thickness
- You can use the first and fourth backwall for calibration if you enter 3X the thickness and so on
- To restart the exercise click on Reset